You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


Advertisement

ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | RSS | Access Rights | Sign In


  Vol. 50 No. 4, April 1993 TABLE OF CONTENTS
  Online Only
 •  Online First Table of
Contents
  ORIGINAL ARTICLES
 •Online Features
 This Article
 •References
 •Full text PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (38)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Delicious Add to Digg Add to Facebook Add to Reddit Add to Technorati Add to Twitter What's this?

Panic Attacks During Placebo Procedures in the Laboratory

Physiology and Symptomatology

Raymond R. Goetz, PhD; Donald F. Klein, MD; Robert Gully, MA; Jeffrey Kahn, MD; Michael R. Liebowitz, MD; Abby J. Fyer, MD; Jack M. Gorman, MD

Arch Gen Psychiatry. 1993;50(4):280-285.


Abstract



• Heart rate, respiratory measurements, and Acute Panic Inventory symptoms of 17 patients with panic disorder who experienced panic attacks during a placebo infusion (situationally provoked panic) were analyzed and compared with similar data from a group of 19 patients with panic disorder who panicked during lactate infusion. Previously, it was shown that the group with lactate-induced panic attacks exhibited increased minute ventilation compared with normal control subjects and nonpanicking patients with panic disorder during lactate infusion. The group with situationally provoked panic attacks exhibited significant increases in both heart rate and minute ventilation immediately preceding the onset of the panic attack. The increase in minute ventilation appeared to be caused more by increase in tidal volume than in respiratory frequency. The increase in heart rate in the group with situationally provoked panic attacks was very similar to that seen in the group with lactate-induced panic attacks, but the group with situationally provoked panic attacks appeared to have somewhat greater increase in minute ventilation than the group with lactate-induced panic attacks. This suggests that the metabolic alkalosis produced by lactate infusion might actually blunt the full expression of panic-associated respiratory stimulation. These data validate the belief that significant cardiorespiratory stimulation occurring during panic attacks in the laboratory is not simply secondary to the intrinsic physiologic effects of panic-inducing substances such as lactate, yohimbine, and carbon dioxide.



Author Affiliations



From the Biological Studies Unit (Drs Goetz and Gorman), Department of Therapeutics (Drs Klein, Liebowitz, and Fyer), New York State Psychiatric Institute, the Department of Psychiatry, College of Physicians and Surgeons of Columbia University (Drs Goetz, Klein, Liebowitz, Fyer, and Gorman), New York, NY; Department of Psychiatry, Payne Whitney Clinic, Cornell University, Ithaca, NY (Dr Kahn); and Pharmaco Dynamics Research, Austin, Tex (Mr Gully).


Footnotes



Accepted for publication March 20, 1992.

Reprint requests to Department of Psychiatry, College of Physicians and Surgeons of Columbia University, 722 W 168th St, New York, NY 10032 (Dr Gorman).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Delicious Delicious   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Somatic Symptoms and Physiologic Responses in Generalized Anxiety Disorder and Panic Disorder: An Ambulatory Monitor Study
Hoehn-Saric et al.
Arch Gen Psychiatry 2004;61:913-921.
ABSTRACT | FULL TEXT  

Response Differences of Spontaneous Panic and Fear
Klein
Arch Gen Psychiatry 2002;59:567-569.
FULL TEXT  

Panic Disorder-A Malfunction of Multiple Transmitter Control Systems within the Midbrain Periaqueductal Gray Matter?
Lovick
Neuroscientist 2000;6:48-59.
ABSTRACT  

Plasma Cortisol Concentrations Preceding Lactate-Induced Panic: Psychological, Biochemical, and Physiological Correlates
Coplan et al.
Arch Gen Psychiatry 1998;55:130-136.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | PHYSICIAN JOBS | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1993 American Medical Association. All Rights Reserved.